Secure Monitor
Jump to navigation
Jump to search
Secure Monitor Calls
The secure monitor provides two top level handlers of which each provides a range of sub handlers.
Secure Monitor Calls follow the ARM SMC calling convention up to a small change:
Bit number | Bit mask | Description |
---|---|---|
31 | 0x80000000 | Set to 0 means Yielding Call; Set to 1 means Fast Call. |
30 | 0x40000000 | Set to 0 means SMC32 convention; Set to 1 means SMC64. |
29-24 | 0x3F000000 | Service Call ranges. |
23-16 | 0x00FF0000 | Must be zero. |
15-8 | 0x0000FF00 | Argument type. This is different from the ARM SMC calling convention. |
7-0 | 0x000000FF | Function number within the range call type. |
If bit n is set in the argument type then parameter Xn is treated as a pointer and the kernel will setup address translation for it in svcCallSecureMonitor.
Id 0
Functions exposed to user-mode processes using svcCallSecureMonitor.
Sub-Id | Name | In | Out |
---|---|---|---|
0xC3000401 | SetConfig | ||
0xC3000002 | GetConfig (Same as Id 1 Sub-Id 4.) | ||
0xC3000003 | CheckStatus_5_9_F_10 | ||
0xC3000404 | GetResult_5_9_F_10 | ||
0xC3000E05 | ExpMod | ||
0xC3000006 | PrngX931 (Same as Id 1 Sub-Id 5.) | ||
0xC3000007 | KeygenAndSealX | ||
0xC3000008 | SetKeyslotFromXY | ||
0xC3000009 | SymmetricCrypto | ||
0xC300000A | KeygenA | ||
0xC300040B | CMAC | ||
0xC300100C | ImportParamsFor10WithXY | ||
0xC300100D | DecryptExpModParamsWithXY | ||
0xC300100E | ImportParamsForFWithXY | ||
0xC300060F | ExpMod | ||
0xC3000610 | ExpModAndKeygenAndSealZ | ||
0xC3000011 | SetKeyslotFromZ | ||
0xC3000012 | KeygenAndSealZ |
Id 1
Functions exposed to the kernel internally.
Sub-Id | Name | In | Out |
---|---|---|---|
0xC4000001 | CPU_SUSPEND (oyasumi) | ||
0x84000002 | CPU_OFF | ||
0xC4000003 | CPU_ON | ||
0xC3000004 | GetConfig (Same as Id 0 Sub-Id 2.) | ||
0xC3000005 | PrngX931 (Same as Id 0 Sub-Id 6.) | ||
0xC3000006 | Panic | ||
0xC3000007 | |||
0xC3000008 | ReadWriteRegister |