Created page with "This page documents how the Ring Fit Adventure game uses hidbus for using the Ring-Con ExternalDevice, which attaches to Joy-Cons. The HID_services#..."
 
No edit summary
Line 6: Line 6:


Commands (input data for EnableJoyPollingReceiveMode / SendAndReceive) start with the u32 cmd, there's generally no data after that. Data in the replies are at least 0x4-bytes, with fields being 4-byte aligned. Reply+0 is the u8 status. When the output size doesn't match the expected size, or status is non-zero, error 0xEDA is returned. When status is non-zero, a func is called with the status value which updates global state.
Commands (input data for EnableJoyPollingReceiveMode / SendAndReceive) start with the u32 cmd, there's generally no data after that. Data in the replies are at least 0x4-bytes, with fields being 4-byte aligned. Reply+0 is the u8 status. When the output size doesn't match the expected size, or status is non-zero, error 0xEDA is returned. When status is non-zero, a func is called with the status value which updates global state.
= CRC =
Some commands/replies use CRC(s) for validating the previous N-bytes prior to the CRC. When the CRC is invalid, the app sets an output flag indicating invalid CRC and skips writing output-data to the output-param.
This CRC doesn't use Xor(In/Out)/Reflect(In/Out). The polynomial is 0x8D.

Revision as of 18:19, 13 March 2020

This page documents how the Ring Fit Adventure game uses hidbus for using the Ring-Con ExternalDevice, which attaches to Joy-Cons.

The BusType used with GetBusHandle is value 0 or 1.

The ExternalDeviceId is 0x20. After EnableExternalDevice is used successfully during initialization, EnableJoyPollingReceiveMode(flag=true) is used with 4-byte command 0x020101. For cleanup, DisableJoyPollingReceiveMode is used then on success EnableExternalDevice(flag=false) is used.

Commands (input data for EnableJoyPollingReceiveMode / SendAndReceive) start with the u32 cmd, there's generally no data after that. Data in the replies are at least 0x4-bytes, with fields being 4-byte aligned. Reply+0 is the u8 status. When the output size doesn't match the expected size, or status is non-zero, error 0xEDA is returned. When status is non-zero, a func is called with the status value which updates global state.

CRC

Some commands/replies use CRC(s) for validating the previous N-bytes prior to the CRC. When the CRC is invalid, the app sets an output flag indicating invalid CRC and skips writing output-data to the output-param.

This CRC doesn't use Xor(In/Out)/Reflect(In/Out). The polynomial is 0x8D.